Philemon smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology.
Smart electromagnetic flow meter is hallmarked by its high performance and reliability that are based on successful, field-proven technology.
Installation Notice
Installed at the lowest point and vertical upward direction Install exhaust valve at the downstreat of flow meter
Don’t install at the highest point and vertical downward diection when drop is more than 5m
Installed at the lowest point when used in open drain pipe Need 10D of upstreat and 5D of downstreat
exit of pump
Size |
DN3-DN3000mm (1/8”~120”) |
Accuracy |
±0.5% of reading,velocity >0.3 m/s |
Conductivity |
Normal liquid >5 μS/cm,DI water >20 μS/cm |
Velocity |
0.1-15 m/s |
Protection Grade |
IP65 Compact, IP68 Seperated |
Power Supply |
AC85~250V, DC20V~36V |
Electrode Type |
Fixed, Scraper |
Power Consumption |
<20W |
Signal Output |
4~20 mA,pulse |
Communication |
RS485/Modbus,Hart over 4~20 mA, Hart,Profitbus |
Language |
English,Chinese (Other languages can be provided on request) |
Display |
LC Display,128X128mm, Three lines, 4 internal push buttons |
Ambient Temperature |
-25 ~ +60℃ /-77 ~ 140℉ Sensor -10~ +60℃ /-50~140℉ Convertor |
Liquid Temperature |
Integrated: 70℃/ 158℉ max Seperated: 200℃/ 392℉max |
Relative Humidity |
5%~90% |
Exciting Current |
125mA, 187mA, 250mA, 500mA |
Exciting Frequency |
25Hz, 3.125Hz, 2.5Hz, 2Hz |
Measuring Tube |
Stainless Steel 304 |
Flange |
Carbon Steel (standard) |
Straight Pipe |
Inlet Path ≥ 10D, Outlet Path ≥ 5D |
Certificates |
CE 6022120716, ISO9001:2008, CQC1500155689521 |
Frequency Output |
1~5000 Hz |
Electrode |
SS316L (standard), Hastelloy C, Hastelloy B,Titanium Tantalum, |
Liner Material |
PTFE DN15-DN1600 -20℃ ~ +120 ℃ (-68℉~ 248℉) |
Process Pressure |
4.0 MPa (DN3-DN150) |
Flange Standard |
ANSI B16.5 150#, 300#, 600# |
QTLD Fmag S1-P1-L1-B1-K1-F1-D1-G1-C1-H1 |
||||||||||||
Structure |
Integrated |
S1 |
|
|
|
|
|
|
|
|
|
|
Seperated |
S2 |
|||||||||||
Nominal
Pressure |
0.6MPa |
P1 |
||||||||||
1.0MPa |
P2 |
|||||||||||
1.6MPa |
P3 |
|||||||||||
4.0MPa |
P4 |
|||||||||||
Liner |
PTFE DN15-DN1600 -20℃~ 120 ℃ |
L1 |
||||||||||
PFA DN3-DN800 -20℃~ 120 ℃ |
L2 |
|||||||||||
F46 DN25-DN1800 -20℃~ 120 ℃ |
L3 |
|||||||||||
Neoprene DN40-DN3000 -10℃~ 80℃ |
L4 |
|||||||||||
Polyurethane DN40-DN1600 -10℃ ~ 60℃ |
L5 |
|||||||||||
FLS DN40-DN1800 -10℃ ~ 200℃ |
L6 |
|||||||||||
Electrode |
Stainless steel 316L |
E1 |
||||||||||
Hastelloy B |
E2 |
|||||||||||
Hastelloy C |
E3 |
|||||||||||
Titanium |
E4 |
|||||||||||
Platinum-iridium |
E5 |
|||||||||||
Tantalum |
E6 |
|||||||||||
Stainless steel covered with tungsten carbide |
E7 |
|||||||||||
Body Material |
Carbon Steel |
B1 |
||||||||||
Stainless steel 304 |
B2 |
|||||||||||
Stainless steel 316L |
B3 |
|||||||||||
Flange
Standard |
ANSI 150#, 300#, 600# |
F1 |
||||||||||
JIS 10K, 20K, 40K |
F2 |
|||||||||||
DIN PN10,PN16,PN25,PN40 |
F3 |
|||||||||||
Power Supply |
AC85~250V |
D1 |
||||||||||
DC20V~36V |
D2 |
|||||||||||
Signal Output |
4~20 mA |
G1 |
||||||||||
Pulse |
G2 |
|||||||||||
Communication |
Modbus-RS485 |
C1 |
||||||||||
Hart |
C2 |
|||||||||||
Profitbus |
C3 |
|||||||||||
Protection
Grade |
IP65 Integrated |
H1 |
||||||||||
IP68 Seperated |
H2 |
|||||||||||
Electrode Type |
Fixed |
D1 |
||||||||||
Scraper |
D2 |
Electrode Material |
Applications |
Stainless Steel 316L |
Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,chemistry,carbamide,etc |
Hastelloy B (HB) |
Having strong resistance to hydrochloric acid of any consistance which is below bioling piont. |
Hastelloy C (HC) |
Be resistant to oxidable acid such as nitric acid,mixed acid,as well as oxidable salt such as Fe+++,Cu++aStnd sea water |
Titanium |
Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid (including fuming nitric acid),organic acid,alkali etc. |
Tantalum |
Having strong resistance to corrosive mediums that is similar with glass |
Platinum-iridium |
Almost be applicable in all chemical mediums except for ammonium salt. |
Stainless Steel Covered |
Applicable in mediums of no corrosive and low abrasion. |
Size |
DN3-DN3000mm (1/8”~120”) |
Accuracy |
±0.5% of reading,velocity >0.3 m/s |
Conductivity |
Normal liquid >5 μS/cm,DI water >20 μS/cm |
Velocity |
0.1-15 m/s |
Protection Grade |
IP65 Compact, IP68 Seperated |
Power Supply |
AC85~250V, DC20V~36V |
Electrode Type |
Fixed, Scraper |
Power Consumption |
<20W |
Signal Output |
4~20 mA,pulse |
Communication |
RS485/Modbus,Hart over 4~20 mA, Hart,Profitbus |
Language |
English,Chinese (Other languages can be provided on request) |
Display |
LC Display,128X128mm, Three lines, 4 internal push buttons |
Ambient Temperature |
-25 ~ +60℃ /-77 ~ 140℉ Sensor -10~ +60℃ /-50~140℉ Convertor |
Liquid Temperature |
Integrated: 70℃/ 158℉ max Seperated: 200℃/ 392℉max |
Relative Humidity |
5%~90% |
Exciting Current |
125mA, 187mA, 250mA, 500mA |
Exciting Frequency |
25Hz, 3.125Hz, 2.5Hz, 2Hz |
Measuring Tube |
Stainless Steel 304 |
Flange |
Carbon Steel (standard) |
Straight Pipe |
Inlet Path ≥ 10D, Outlet Path ≥ 5D |
Certificates |
CE 6022120716, ISO9001:2008, CQC1500155689521 |
Frequency Output |
1~5000 Hz |
Electrode |
SS316L (standard), Hastelloy C, Hastelloy B,Titanium Tantalum, |
Liner Material |
PTFE DN15-DN1600 -20℃ ~ +120 ℃ (-68℉~ 248℉) |
Process Pressure |
4.0 MPa (DN3-DN150) |
Flange Standard |
ANSI B16.5 150#, 300#, 600# |